Remote Operation
Syntax: *ESE <NRf>
Parameter: 0 to 255
Example: *ESE 48 This command enables the CME and EXE events
of the Standard Event Status Event register.
Query Syntax: *ESE?
Return Parameter: <NR1>
Query Example: *ESE? This query returns current setting of Standard
Event Status Enable.
*ESR? Standard Event Status Register
Type: Device status
Description: This query reads the Standard Event Status register and clears it.
Query Syntax: *ESR?
Return Parameter: <NR1>
Query Example: *ESR? Return status readings of Standard Event Status register.
Return Example: 48
*IDN? Identification Query
Type: System interface
Description: This query requests the 62000P to identify itself.
Query Syntax: *IDN?
Return Parameter: <aard>
Query Example: *IDN?
String Description
CHROMA Manufacture
62012P Model name
01.00 Firmware version
2005/07/14 Date
Return Example: CHROMA 62012P-80-60, 01.00,2005/07/14
*OPC Operation Complete Command
Type: Device status
Description: This command causes the interface to set the OPC bit (bit 0) of the
Standard Event Status register when the 62012P Series has completed all
pending operations.
Syntax: *OPC
Parameter: None
*OPC? Operation Complete Query
Type: Device status
Description: This query returns an ASCII “1” when all pending operations are
completed.
Query Syntax: *OPC?
Return Parameter: <NR1>
Query Example: 1