EasyManua.ls Logo

Chroma 62000P Series - MEASURE Subsystem; PROGRAM Subsystem

Chroma 62000P Series
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable DC Power Supply 62000P Series Operating & Programming Manual
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:POW?
Return Example: 1100.00
(4) FETCh:STATus?
Description: It returns the status code of Power Supply’s state.
Query Syntax: FETCh:STATus?
Return Parameter: Status Code
5.6.2.5 MEASURE Subsystem
(1) MEASure:VOLTage?
Description: It returns the voltage measured at the output of Power Supply.
Query Syntax: MEASure:VOLTage?
Return Parameter: <NRf+> [Unit Voltage]
Query Example: MEAS:VOLT?
Return Example: 8.12
(2) MEASure:CURRent?
Description: It returns the current measured at the output of Power Supply.
Query Syntax: MEASure:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:CURR?
Return Example: 3.15
(3) MEASure:POWer?
Description: It returns the power measured at the output of Power Supply.
Query Syntax: MEASure:POWer?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:POW?
Return Example: 1000.00
5.6.2.6 PROGRAM Subsystem
(1) PROGram: SELected
Description: It sets the executed program no.
Syntax: PROGram: SELected <NR1>
Parameter: 1 to 10
Example: PROG:SEL 10
Query Syntax: PROG:SEL? It returns the program no. in use.
Return Parameter: <NR1>
Query Example: PROG:SEL?
Return Example: 10
(2) PROGram:LINK
Description: It links a program to another when ends.
Syntax: PROGram:LINK <NR1>
5-14

Table of Contents