Programmable DC Power Supply 62000P Series Operating & Programming Manual
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:POW?
Return Example: 1100.00
(4) FETCh:STATus?
Description: It returns the status code of Power Supply’s state.
Query Syntax: FETCh:STATus?
Return Parameter: Status Code
5.6.2.5 MEASURE Subsystem
(1) MEASure:VOLTage?
Description: It returns the voltage measured at the output of Power Supply.
Query Syntax: MEASure:VOLTage?
Return Parameter: <NRf+> [Unit Voltage]
Query Example: MEAS:VOLT?
Return Example: 8.12
(2) MEASure:CURRent?
Description: It returns the current measured at the output of Power Supply.
Query Syntax: MEASure:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:CURR?
Return Example: 3.15
(3) MEASure:POWer?
Description: It returns the power measured at the output of Power Supply.
Query Syntax: MEASure:POWer?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:POW?
Return Example: 1000.00
5.6.2.6 PROGRAM Subsystem
(1) PROGram: SELected
Description: It sets the executed program no.
Syntax: PROGram: SELected <NR1>
Parameter: 1 to 10
Example: PROG:SEL 10
Query Syntax: PROG:SEL? It returns the program no. in use.
Return Parameter: <NR1>
Query Example: PROG:SEL?
Return Example: 10
(2) PROGram:LINK
Description: It links a program to another when ends.
Syntax: PROGram:LINK <NR1>
5-14