Programmable DC Power Supply 62000P Series Operating & Programming Manual
3.3.7.4 APG Voltage Calibration
3.3.7.4.1 Hardware Requirements
Device Suggest Model or Capacity
DVM HP 34401A or equivalent DVM
DC Power Supply Any DC Power Supply or DC signal source
that can output 10Vdc and drive 100mA.
Table 3-11
3.3.7.4.2 SETUP
123456
+12VA APIGND V SET I SET V
MEAS.
I
MEAS.
+
+
DC Power
Supply
DVM1 DVM2
+
Figure 3-96
3.3.7.4.3 Calibration Procedure (Example: Model 62012P-80-60)
(1) In CALIBRATION page, press “
3
” or turn “Rotary” (
) knob to set CHOICE = 3.
(2) Press
ENTER
” to confirm entering into APG Voltage Calibration options as Figure 3-97
shows.
[APG VOLT
A
GE CAL I B
R
A
T I O N ]
C H E C
K
A P G C O N N E C T I O N A N D P
R
ESS [ E N T E
R
]
( S E T ) I N P U T V O L T A G E F O R S E T T I N G = 0 . 5
V
A
C T U
A
L A P G I N P U T V O L T A G E = 0 . 6 6 V
( S E T ) I N P U T V O L T A G E F O R S E T T I N G = 8 . 0
V
A
C T U
A
L A P G I N P U T V O L T A G E = 8 . 6 8 V
Figure 3-97