Remote Operation
5.6.2 Specific GPIB Commands for 62012P Series
5.6.2.1 ABORT Subsystem
ABORt
Description: It sets all output state to “OFF”.
Syntax: ABORt
5.6.2.2 CONFIGURE Subsystem
(1) CONFigure: TTLport
Description: It sets the output value for TTL Port.
Syntax: CONFigure:TTL <NR1>
Parameter: <NR1>
Example: CONF:TTL 0
CONF:TTL 255
Query Syntax: CONFigure:TTL?
Return Parameter: <NR1>
Query Example: CONF:TTL? It returns the output value of TTL Port.
Return Example: 0 or 255
(2) CONFigure:BEEPer
Description: It sets the beeper to ON or OFF.
Syntax: CONFigure:BEEPer ON
CONFigure:BEEPer OFF
Parameter: ON/1, OFF/0
Example: CONF: BEEPer ON
CONF: BEEPer OFF
Query Syntax: CONFigure:BEEPer?
Return Parameter: <NR1>
Query Example: CONF:BEEPer? It returns the beeper control status.
Return Example: 0 or 1
(3) CONFigure:REMote
Description: It sets the remote control status (valid for RS232C only).
Syntax: CONFigure:REMote ON
CONFigure:REMote OFF
Parameter: ON/1, OFF/0
Example: CONF:REM ON It is set to remote control.
(4) CONFigure:OUTPut
Description: It sets the output voltage/current.
Syntax: CONFigure:OUTPut ON
CONFigure: OUTPut OFF
Parameter: ON/start output, OFF/stop output
Example: CONFigure: OUTPut The power supply starts output.
CONFigure: OUTPut OFF The power supply stops outpu.
Query Syntax: CONFigure: OUTPut?
5-9