Remote Operation
current protection.
Return Example: 50.00
(8) SOURce:CURRent:SLEW
Description: It sets the rising or falling slew rate (amp/ms) of output current.
Syntax: SOURce:CURRent:SLEW <NR1>[suffix]
SOURce:CURRent:SLEW <NR1>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOUR:CURR:SLEW 0.01 It sets the output current slew rate to
0.01 Amp/mS.
SOUR:CURR:SLEW 1.00 It sets the output current slew rate to
1.00 Amp/mS.
Query Syntax: SOUR:CURR:SLEW?
Return Parameter: <NR1> [Unit Amp/ms]
Query Example: SOUR:CURR:SLEW? It returns the current slew rate.
Return Example: 1.00
(9) SOURce:POWer:PROTect:HIGH
Description: It sets the over power point(Watt) of output power.
Syntax: SOURce:POWer:PROTect:HIGH <NR1>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOURce:POWer:PROTect:HIGH 1260 It sets the over power
point 1260.
Query Syntax: SOURce:POWer:PROTect:HIGH?
Return Parameter: <NR1> [Watt]
Query Example: SOURce:POWer:PROTect:HIGH? It returns the over power
setting value.
Return Example: 1260.00
5.6.2.4 FETCH Subsystem
(1) FETCh:VOLTage?
Description: It measures the output of Power Supply and returns real time voltage.
Query Syntax: FETCh:VOLTage?
Return Parameter: <NRf+> [Unit Volt]
Query Example: FETC:VOLT?
Return Example: 8.12
(2) FETCh:CURRent?
Description: It measures the output of Power Supply and returns real time current.
Query Syntax: FETCh:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:CURR?
Return Example: 3.15
(3) FETCh:POWer?
Description: It measures the output of Power Supply and returns real time power.
Query Syntax: FETCh:POWer?
5-13