Programmable DC Power Supply 62000P Series Operating & Programming Manual
Syntax: SOURce:VOLTage:SLEW <NR1>[suffix]
SOURce:VOLTage:SLEW <NR1>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOUR:VOLT:SLEW 0.01 It sets the output voltage slew rate to
0.01volt/mS
SOUR:VOLT:SLEW 10 It sets the output voltage slew rate to
100 volt/mS
Query Syntax: SOUR:VOLT:SLEW?
Return Parameter: <NR1> [Unit Volt/ms]
Query Example: SOUR:VOLT:SLEW? It returns the voltage slew rate.
Return Example: 10
(5) SOURce: CURRent
Description: It sets the output current (ampere).
Syntax: SOURce:CURRent <NRf+>[suffix]
SOURce:CURRent <NRf+>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOUR:CURR 1 It sets the output current to 1 amps.
SOUR:CURR 60.00 It sets the output current to 60.00 amps.
Query Syntax: SOUR:CURR?
Return Parameter: <NRf+> [Unit Amp]
Query Example: SOUR:CURR? It returns the current.
Return Example: 9.000000e1
(6) SOURce:CURRent:LIMit:{HIGH/LOW}
Description: It sets the output current range.
Syntax: SOURce:CURRent:LIMIT:HIGH <NRf+>[suffix]
SOURce:CURRent:LIMIT:LOW <NRf+>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOUR:CURR:LIMIT:HIGH 60.0 It sets the output current range
to 60A maximum.
SOUR:CURR:LIMIT:LOW 20.0 It set the low limit to 20A for
current output protection.
Query Syntax: SOUR:CURR:LIMIT:HIGH?
SOUR:CURR:LIMIT:LOW?
Return Parameter: <NRf+> [Unit Amp]
Query Example: SOUR:CURR:LIMIT:HIGH? It returns the maximum range set
for current.
Return Example: 60.00
(7) SOURce:CURRent:PROTect:{HIGH }
Description: It sets the current range for over current protection.
Syntax: SOURce:CURRent:PROTect:HIGH <NRf+>[suffix]
Parameter: Refer to individual spec for valid numeric range.
Example: SOUR:CURR:PROT:HIGH 60.0 It sets the high limit to 60Amp
for current output protection.
Query Syntax: SOUR:CURR:PROT:HIGH?
Return Parameter: <NRf+> [Unit Amp]
Query Example: SOUR:CURR:PROT:HIGH? It returns the high limit of
5-12

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 62000P Series and is the answer not in the manual?

Chroma 62000P Series Specifications

General IconGeneral
BrandChroma
Model62000P Series
CategoryPower Supply
LanguageEnglish

Related product manuals