Parameter: 0 to10 (0 is not linked)
Example: PROG:LINK 7
Query Syntax: PROG:LINK?
Return Parameter: <NR1>
Query Example: PROG:LINK?
Return Example: 7
(3) PROGram:COUNT
Description: It sets the program file to be executed in series.
Syntax: PROGram:COUNT <NR1>
Parameter: 1 to 15000
Example: PROG:COUNT 7
Query Syntax: PROG: COUNT ?
Return Parameter: <NR1>
Query Example: PROG: COUNT ?
Return Example: 7
(4) PROGram:RUN
Description: It executes the program.
Syntax: PROGram:RUN ON
PROGram:RUN OFF
Parameter: ON/1, OFF/0
Example: PROG:RUN ON
Query Syntax: PROGram:RUN?
Return Parameter: <NR1>
Query Example: PROGram:RUN?
Return Example: 1
(5) PROGram:SAVE
Description: It saves the program.
Syntax: PROGram:SAVE
Parameter: None
Example: PROG:SAVE
(6) PROGram:SEQuence:SELected
Description: It sets the execution sequence of a program.
Syntax: PROGram:SEQuence:SELected <NR1>
Parameter: 1 to 10
Example: PROG:SEQ:SEL 3
Query Syntax: PROGram:SEQuence:SELected?
Return Parameter: <NR1>
Query Example: PROG:SEQ:SEL?
Return Example: 3
(7) PROGram:SEQuence:TYPE
Description: It sets the action type of sequence.
Syntax: PROGram:SEQuence:TYPE TRI
PROGram:SEQuence:TYPE AUTO
PROGram:SEQuence:TYPE MANUAL
5-15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 62000P Series and is the answer not in the manual?

Chroma 62000P Series Specifications

General IconGeneral
BrandChroma
Model62000P Series
CategoryPower Supply
LanguageEnglish

Related product manuals