7-3
Cisco ME 3800X and 3600X Switch Software Configuration Guide
OL-23400-01
Chapter 7 Configuring the Switch External Alarms
Configuring Switch Alarms
This example configures alarm input 2 named door sensor to assert a major alarm when the door circuit
is closed and then displays the status and configuration for all alarms:
Switch(config)# alarm-contact 2 description door sensor
Switch(config)# alarm-contact 2 severity major
Switch(config)# alarm-contact 2 trigger closed
Switch(config)# end
Switch(config)# show env alarm-contact
Switch# show env alarm-contact
ALARM CONTACT 1
Status: not asserted
Description: test_1
Severity: critical
Trigger: open
ALARM CONTACT 2
Status: not asserted
Description: door sensor
Severity: major
Trigger: closed
ALARM CONTACT 3
Status: not asserted
Description: flood sensor
Severity: critical
Trigger: closed
ALARM CONTACT 4
Status: not asserted
Description:
Severity: critical
Trigger: closed