EasyManuals Logo

Cisco 8832 Administration Guide

Cisco 8832
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
DescriptionField
This check box determines whether you allow the EnergyWise domain controller policy to send
power level updates to the phones. The following conditions apply:
One or more days must be selected in the Enable Power Save Plus field.
The settings in Cisco Unified Communications Manager Administration take effect on
schedule even if EnergyWise sends an override.
For example, assuming the Phone Off Time is set to 22:00 (10:00 p.m.), the value in the Phone
On Time field is 06:00 (6:00 a.m.), and the Enable Power Save Plus has one or more days selected.
If EnergyWise directs the phone to turn off at 20:00 (8:00 p.m.), that directive remains in
effect (assuming no phone user intervention occurs) until the configured Phone On Time at
6:00 a.m.
At 6:00 a.m., the phone turns on and resumes receiving the power level changes from the
settings in Unified Communications Manager Administration.
To change the power level on the phone again, EnergyWise must reissue a new power level
change command.
To disable Power Save Plus, you must uncheck the Allow EnergyWise Overrides check
box. If the Allow EnergyWise Overrides remains checked but no days are selected in
the Enable Power Save Plus field, Power Save Plus is not disabled.
Note
Allow EnergyWise Overrides
Step 4 Select Save.
Step 5 Select Apply Config.
Step 6 Restart the phone.
Set Up Do Not Disturb
When Do Not Disturb (DND) is turned on, either no audible rings occur during the ringing-in state of a call,
or no audible or visual notifications of any type occur.
When Do Not Disturb (DND) is turned on, the header on the conference phone screen is red.
For more information, see the do not disturb information in the documentation for your particular Cisco
Unified Communications Manager release.
Procedure
Step 1 In Cisco Unified Communications Manager Administration, select Device > Phone.
Step 2 Locate the phone to be configured.
Step 3 Set the following parameters.
Do Not Disturb: This check box allows you to enable DND on the phone.
DND Option: Ring Off, Call Reject, or Use Common Phone Profile Setting.
Cisco IP Conference Phone 8832 Administration Guide for Cisco Unified Communications Manager
109
Cisco IP Conference Phone Administration
Set Up Do Not Disturb

Table of Contents

Other manuals for Cisco 8832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 8832 and is the answer not in the manual?

Cisco 8832 Specifications

General IconGeneral
Control typeButtons
Display typeLCD
Product typeIP conference phone
Voice codecsG.711a, G.711u, G.722, G.729A, G.729ab, OPUS, iLBC
CertificationCE Markings per directives 2014/30/EU and 2014/53/EU and 2014/35/EU \u2028 \u2028 UL 60950 Second Edition \u2028 CAN/CSA-C22.2 No. 60950 Second Edition \u2028 EN 60950 Second Edition (including A11 and A12) IEC 60950 Second Edition (including A11 and A12) EN 60950-1 IEC 60950-1 AS/NZS 60950.1 47CFR Part 15 (CFR 47) Class B AS/NZS CISPR32 Class B \u2028 CISPR32 \u2028Class B EN55032 \u2028 Class B EN 300 386 ICES003 Class B \u2028 VCCI Class B \u2028 EN61000-3-2 \u2028 EN61000-3-3 \u2028 EN61000-4-2 IEC61000-4-2 EN61000-4-3 IEC61000-4-3 EN61000-4-6 IEC61000-4-6 KN22 Class B \u2028 EN55024 \u2028 CISPR24 \u2028 KN24 Armadillo Light AS/ACIF S004 NZPTC220
Product colorCharcoal
Frequency range100 - 20000 Hz
Built-in displayYes
Display diagonal3.9 \
Languages supportARA, BUL, CAT, CHI (SIMPL), CHI (TR), CZE, DAN, DEU, DUT, ENG, ESP, EST, FIN, FRE, GRE, HEB, HUN, ITA, JPN, KOR, LAT, LIT, NOR, POL, POR, RUM, RUS, SER, SLK, SLV, SWE, TUR, UKR
Display resolution480 x 128 pixels
Security algorithmsEAP-FAST, EAP-TLS, SHA-256, SSH
Ethernet LAN data rates10, 100 Mbit/s
Ethernet interface typeFast Ethernet
Supported network protocolsIPv4, IPv6, SIP, SDP, UDP, DHCP, GARP, TFTP, HTTPS, RTP, RTCP, Cisco Discovery Protocol, LLDP
Cables includedUSB
Storage temperature (T-T)-10 - 60 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)10 - 95 %
Operating relative humidity (H-H)10 - 90 %
USB connector typeUSB Type-C
RJ-45 ports quantity1
Weight and Dimensions IconWeight and Dimensions
Width278 mm
Height61 mm
Weight1850 g

Related product manuals