Compaq Deskpro EN Series of Personal Computers D-7
Table D-11
Continued
Error
Code Description Recommended Action
2458-xx Advanced VGA BitBLT test. The following steps apply to error codes 2458-xx through
2480-xx:
2468-xx Advanced VGA DAC test. 1. Replace the video board and retest.
2477-xx Advanced VGA data path test. 2. Replace the system board and retest.
2478-xx Advanced VGA BitBLT test.
2480-xx Advanced VGA Linedraw test.
Table D-12
Audio Test Error Codes
Error
Code Description Recommended Action
3206-xx Audio System Internal Error. Replace the system board and retest.
Note: When Windows 95 is installed, changes to ESS sound device configuration do not take effect until the
computer is restarted (turned off and on).
Table D-13
Network Interface Test Error Codes
Error
Code Description Recommended Action
6000-xx Network ID test failed. The following steps apply to error codes 6000-xx through
6089-xx:
6014-xx Network configuration test failed.* 1. Run Computer Setup or Windows NT or Windows 95
utilities.
6016-xx Network reset test failed.* 2. Verify test procedures.
6028-xx Network internal test failed.* 3. Replace the network board, if installed.
6029-xx Network external test failed.* 4. Replace the system board.
6054-xx Network configuration test failed.**
6056-xx Network reset test failed.**
6068-xx Network internal test failed.**
6069-xx Network external test failed.**
6089-xx Network open test failed.**
* Ethernet only.
**Token Ring only.