CTH200 Series PLC User Manual
Filter can smooth the weighing value and resist disturbance. The last weight is an average of n
measurements; 50Hz sample frequency means weigh every 20 ms. For example, filter depth
n=10 represents taking 10 measurements for average value and recalculate every 20ms.
If the interfering frequency integral multiple of “1/(filter depth * 20 ms)”, then the average filter will
realize brilliant damping of cycle disturbance.
3. Weight_Default
Call it by SM0.0, set Mode 1 for second calibration. The parameter will automatically assign
value when using 231-7WA module for first time with loading factory setting. Refer to instruction
explanation before for details.
Mode explanation
Weighing module SM231-7WA offers 2 usages by configure parameter in “Mode" of
"Weight_Default' to select basic mode or expansion mode.
1) Basic mode (Mode=0)
(1) Call “Weight_Config”, "Weight_Init" and "Weight_Default";
(2) Supported following functions:
• Set sensor sensitivity, low pass cutoff frequency and filter depth;
• Load factory parameter;
• Set maximum weighing range;
• Set zero;
• First calibration;
• Measure tare;
• Delete tare;
• Read sampling value both before and after filtering;
• Power-down alarm, line broke alarm, outrange alarm and set zero etc.
2) Expansion mode (Mode=1)
(1) Call "Weight_Config", "Weight_Init", "Weight_Default" and "Weight_Extend";
(2) Support following functions:
• Supported all functions in basic mode;
• Set minimum weighing range;
• Second calibration;
• Preset tare;
• Set Digital phase (set minimum range scale, show in 1×10
k
, 2×10
k
or 5×10
k
)
• Ensure pause status (set pause status when setting zero and tare)
• Newly added status: Max+9e (GB/T 7724-2008), Preseted tare, 1/4d (GB/T 23111-2008), pause,
low weight;