Secon 10 - Diagnosc and Maintenance Procedures
Technical Manual
Error Message Fault Description Additional information
Card Reader No Comms The MDB card reader is not
responding to commands.
Check power to card reader, wiring and
connecons
Card Reader Manuf Trans
Error
The card reader reports that
there is a manufacturers
transient error.
Card Reader Comms Error The card reader reports that
there is a communicaons
error.
Card Reader Service Error The card reader reports that
there is a service error.
Card Reader Manufact OOS
Error
The card reader reports that
there is a manufacturers
error and out of service.
Bill Validator No Comms The bill validator is not
responding to commands.
Check power to bill validator, wiring and
connecons
Bill Validator Motor Error The bill validator is reporng
a motor error.
Bill Validator Sensor Error The bill validator is reporng
a sensor error.
Bill Validator ROM Error The bill validator is reporng
a ROM error.
Bill Validator Acceptor
Jammed
The bill validator is reporng
that the acceptor is jammed.
Bill Validator Stacker Error The bill validator is reporng
a stacker error.
Bill Validator Stacker Full The bill validator is reporng
that the stacker is full.
Empty stacker
Bill Validator Disabled The bill validator is reporng
that it is disabled.
Water heang Water temperature in main
boiler is below operang
temperature.
The error is cleared once operang
temperature is achieved by pressure boiler.
The machine will disable all hot drinks using
gravity boiler if the temperature falls below
min vend temperature. The drinks will be
re-enabled once min Vend temperature is
achieved.