Secon 10 - Diagnosc and Maintenance Procedures
Technical Manual
Error Message Fault Description Additional information
Card Reader No Comms The MDB card reader is not
responding to commands.
Check power to card reader, wiring and
connecons
Card Reader Manuf Trans
Error
The card reader reports that
there is a manufacturer’s
transient error.
Card Reader Comms Error The card reader reports that
there is a communicaons
error.
Card Reader Service Error The card reader reports that
there is a service error.
Card Reader Manufact OOS
Error
The card reader reports that
there is a manufacturer’s
error and out of service.
Bill Validator No Comms The bill validator is not
responding to commands.
Check power to bill validator, wiring and
connecons
Bill Validator Motor Error The bill validator is reporng
a motor error.
Bill Validator Sensor Error The bill validator is reporng
a sensor error.
Bill Validator ROM Error The bill validator is reporng
a ROM error.
Bill Validator Acceptor
Jammed
The bill validator is reporng
that the acceptor is jammed.
Bill Validator Stacker Error The bill validator is reporng
a stacker error.
Bill Validator Stacker Full The bill validator is reporng
that the stacker is full.
Empty stacker
Bill Validator Disabled The bill validator is reporng
that it is disabled.
Water heang Water temperature in main
boiler is below operang
temperature.
The error is cleared once operang
temperature is achieved by pressure boiler.
The machine will disable all hot drinks using
gravity boiler if the temperature falls below
min vend temperature. The drinks will be
re-enabled once min Vend temperature is
achieved.