Secon 5 - Engineers Program
Technical Manual
This opon allows the user to decide how they want to set the ingredient throws when
programming the machine, either by me or by volume.
Note: to set up or view using volume (g or ml) ALL the Canisters/Grinder and valves must
be calibrated as described in secon 5.7.1.2
Select Time to program the throws in seconds.
Select View to view the throws in grams or millilitres
Note: this is opon is chronologically based and only allows you to view the current
sengs, when the ingredient is changed and it is recalibrated the values here will not be
changed.
Select Save to program the throws in grams or millilitres
Note: this opon is volume based and when the ingredient is changed and it is recalibrated
the values here will be changed accordingly.
5.7.2 Nutrion Info (all ingredients and valves must have been be calibrated)
See secon 4.14
5.7.3 Copy content from USB sck
See secon 4.6
5.7.4 Remove content from machine
See secon 4.8
5.7.5 Change product informaon
See secon 4.9
5.7.6 Change Group Informaon
See secon 5.3.3
5.7.7 Congure Generic Content
See secon 4.10
5.7.8 Heater Tank Setup
This opon enables the target water temperatures in the tank, the minimum temperature
for a drink to be set and displays the current tank temperature.
1. Minimum Vend Temperature—to set the minimum vend temperature.
2. Tank Temperature—to set the gravity tank temperature.
3. Current Tank Temperature—shows the current gravity tank temperature.
4. CoEx® Temperature—to set the espresso heater temperature.
5. Current CoEx® Temperature—shows the current espresso heater temperature.
73