Secon 5 - Engineer’s Program
Technical Manual
4. CoEx® Cleaning:
a. CoEx® Tablet Clean - Iniates a clean cycle
b. CoEx® Cleaning - enables or disables the mer within the machine soware. If
enabled the machine will show a warning each me the door is open aer seven
days, if the cleaning cycle has not been completed aer ten days all drinks using
the CoEx® brewer will be disabled. A successful clean cycle will reset this mer.
c. Last CoEx® Clean - will show the me and date a CoEx® clean cycle was completed
5. CoEx® Pump Mode - this indicates the selected pump mode, either Single or Dual.
6. CoEx® Flow Rate - this shows the ow rate last recorded through the CoEx® unit any
value above 0.5ml/s is acceptable. If the ow is less it will put the CoEx® module out
of service and display a No Water CoEx® error.
7. Prevend Heat - This enables the brewer components to be ushed through with hot
water aer a period of inacvity. This ensures the brewer components are warm and
therefore the vend hot.
Enabled/Disabled - to enable or disable the Prevend Heat opon.
Water Quanty - enables the amount of hot water used during the ush to be
set.
Inacvity Period - the period of me aer the last vend the ush will occur.
5.7.21 Oltre Brewer
This menu enables the following opons for the Oltre brewer to be set-up.
1. Tea Brewer Vend Counter - this displays the current Tea Brewer Vend Count. There is
also the opon to reset this counter.
2. Tea Belt Usage Counter - this displays the current Tea Belt Usage Count. There is also
the opon to reset this counter. It is recommended that the belt is replaced every 5000
vends to maintain the highest quality drink.
5.7.22 Water Only - No Cup
This disables the cup drop unit and forces the user to use their own cup when vending Hot
or Cold water.
If SureVend
TM
is enabled the user’s cup must be in the dispense area before the water is
dispensed.
5.7.23 Sck Srrer Sengs
This menu enables the conguraon of the dropping of a Sck Srrer, depending on the
drink dispensed and when.
5.7.23.1 Sck Srrer
This opon enables the Sck Srrer dropper to be used, which drinks receive a srrer and
whether it is dropped at the start or end of the vend.
1. Disabled - this disables the Sck Srrer, no srrers are dropped.
2. All Selecons - a Srrer is provided for all drinks.
3. Pre set selecons - a Srrer is provided for all drinks with sugar (as dened in the