in hundredths of a percent.
4.6.1.8.7 RMON Alarm Overview
ID: Display an alarm control index.
Interval: Interval in seconds for sampling and comparing the rising and falling threshold.
Variable: MIB object that is used to be sampled.
Sample Type: The method of sampling the selected variable and calculating the value to be compared against the
thresholds.
Value: The value of the statistic during the last sampling period.
Startup Alarm: The alarm that may be triggered when this entry is first set to valid.
Rising Threshold: If the current value is greater than the rising threshold, and the last sample value was less than this
threshold, then an alarm will be generated.
Rising Index: The index of the event to use if an alarm is triggered by monitored variables crossing above the rising
threshold.
Falling Threshold: If the current value is less than the falling threshold, and the last sample value was greater than this
threshold, then an alarm will be generated.
Falling Index: The index of the event to use if an alarm is triggered by monitored variables crossing below the falling
threshold.
4.6.1.8.8 RMON Event Overview
Event Index: Display the event entry index.
Log Index: Display the log entry index.
Log Time: Display Event log time.
Log Description: Display Event description.