xStack
® 
DGS-3120 Series Managed Switch CLI Reference Guide 
185 
 
<centisecond 250-1000> - Enter the alarm time value here. This value must be between 250 
and 1000 centiseconds. 
alarm_reset_time - (Optional) This is the dormant duration time before a defect is triggered 
before the fault can be re-alarmed. The unit is centisecond, the range is 250-1000. The default 
value is 1000. 
<centisecond 250-1000> - Enter the alarm reset time value here. This value must be 
between 250 and 1000 centiseconds. 
 
Restrictions 
Only Administrator, Operator and Power-User level users can issue this command. 
 
Example 
To configure a CFM MEP: 
DGS-3120-24TC:admin# config cfm mep mepname mep1 state enable ccm enable 
Command: config cfm mep mepname mep1 state enable ccm enable 
 
Success. 
 
 
19-7  delete cfm mep 
Description 
This command is used to delete a previously created MEP. 
 
Format 
delete cfm mep [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index 
<uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] 
 
Parameters 
mepname - Specify the MEP name. 
<string 32> - Enter the MEP name used here. This name can be up to 32 characters long. 
mepid - Specify the MEP ID. 
<int 1-8191> - Enter the MEP ID used here. This value must be between 1 and 8191. 
md - Specify the maintenance domain name. 
<string 22> - Enter the maintenance domain name used here. This name can be up to 22 
characters long. 
md_index - Specify the maintenance domain index. 
<uint 1-4294967295> - Enter the maintenance domain index value here. This value 
must be between 1 and 4294967295. 
ma - Specify the maintenance association name. 
<string 22> - Enter the maintenance association name used here. This name can be up to 
22 characters long. 
ma_index - Specify the maintenance association index. 
<uint 1-4294967295> - Enter the maintenance association index value here. This value 
must be between 1 and 4294967295.