DGS-3120-24TC:admin# disable loopdetect
Command: disable loopdetect
Success.
DGS-3120-24TC:admin#
42-5 show loopdetect
Description
This command is used to display the LBD global configuration.
Format
show loopdetect
Parameters
None.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To show the LBD global settings:
DGS-3120-24TC:admin#show loopdetect
Command: show loopdetect
LBD Global Settings
---------------------------
Status : Disabled
Mode : Port-based
Interval : 10 sec
Recover Time : 60 sec
Trap State : None
Log State : Enabled
DGS-3120-24TC:admin#
42-6 show loopdetect ports
Description
This command is used to display the LBD per-port configuration.
Format
show loopdetect ports {<portlist>}