<temperature -500-500> - Enter the high threshold temperature here.
low - (Optional) To configure low threshold value. n is the low threshold value.
<temperature -500-500>
- Enter the low threshold temperature here.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the warning temperature threshold:
DGS-3120-24TC:admin# config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3120-24TC:admin#
54-4 config temperature
Description
This command is used to configure the trap state for temperature warning event.
Format
config temperature [trap | log] state [enable | disable]
Parameters
trap state - Specify the trap state for the warning temperature event.
enable - Enable trap state for warning temperature event. The default state is enabled.
disable - Disable trap state for warning temperature event.
log state - Specify the log state for the warning temperature event.
enable - Enable log state for warning temperature event. The default state is enabled.
disable - Disable log state for warning temperature event.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the warning temperature threshold:
DGS-3120-24TC:admin# config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3120-24TC:admin#