xStack
® 
DGS-3120 Series Managed Switch CLI Reference Guide 
537 
 
<temperature -500-500> - Enter the high threshold temperature here. 
low - (Optional) To configure low threshold value. n is the low threshold value.  
 - Enter the low threshold temperature here. 
 
Restrictions 
Only Administrator and Operator-level users can issue this command. 
 
Example 
To configure the warning temperature threshold: 
DGS-3120-24TC:admin# config temperature threshold high 80 
Command: config temperature threshold high 80 
 
Success. 
 
DGS-3120-24TC:admin#  
 
54-4  config temperature 
Description 
This command is used to configure the trap state for temperature warning event. 
 
Format 
config temperature [trap | log] state [enable | disable] 
 
Parameters 
trap state - Specify the trap state for the warning temperature event. 
enable - Enable trap state for warning temperature event. The default state is enabled. 
disable - Disable trap state for warning temperature event. 
log state - Specify the log state for the warning temperature event. 
enable - Enable log state for warning temperature event. The default state is enabled. 
disable - Disable log state for warning temperature event. 
 
Restrictions 
Only Administrator and Operator-level users can issue this command. 
 
Example 
To configure the warning temperature threshold: 
DGS-3120-24TC:admin# config temperature threshold high 80 
Command: config temperature threshold high 80 
 
Success. 
 
DGS-3120-24TC:admin#