xStack
® 
DGS-3120 Series Managed Switch CLI Reference Guide 
707 
 
Chapter 77  System Severity Command 
List 
 
config system_severity [trap | log | all] [emergency | alert| critical | error | warning | notice | 
information | debug | <level 0-7>] 
 
77-1  config system_severity 
Description 
This command is used to configure the severity level control for the system. 
When the user chooses a specific level to log or trap, messages at that severity level or more will 
be logged or trapped to SNMP managers. 
 
Format 
config system_severity [trap | log | all] [emergency | alert| critical | error | warning | notice | 
information | debug | <level 0-7>] 
 
Parameters 
trap - Specify the severity level control for traps. 
log - Specify the severity level control for the log. 
all - Specify the severity level control for traps and the log. 
emergency - Severity level 0. 
alert - Severity level 1. 
critical - Severity level 2. 
error - Severity level 3. 
warning - Severity level 4. 
notice - Severity level 5. 
information - Severity level 6. 
debug - Severity level 7. 
<level 0-7> - Enter the severity level here. This value must be between 0 and 7. 
 
Restrictions 
Only Administrator and Operator-level users can issue this command. 
 
Example 
To configure severity level control as information level for trap: 
DGS-3120-24TC:admin#config system_severity trap warning 
Command: config system_severity trap warning 
 
Success. 
 