EasyManuals Logo

D-Link DWC-2000 User Manual

D-Link DWC-2000
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
D-Link DWC-2000 User Manual 96
Section 4 - Advanced WLAN Conguration
Field Description
cwMan (Maximum
Contention Window)
The value specied here in the Maximum Contention Window is the upper limit (in
milliseconds) for the doubling of the random backo value. This doubling continues until
either the data frame is sent or the Maximum Contention Window size is reached.
Once the Maximum Contention Window size is reached, retries will continue until a
maximum number of retries allowed is reached.
Valid values for the cwmax are 1, 3, 7, 15, 31, 63, 127, 255, 511, or 1024. The value for
cwmax must be higher than the value for cwmin.
Max. Burst Length
AP EDCA Parameter Only (The Max. Burst Length applies only to trac owing from the
access point to the client station.) This value species (in milliseconds) the Maximum Burst
Length allowed for packet bursts on the wireless network. A packet burst is a collection
of multiple frames transmitted without header information. The decreased overhead
results in higher throughput and better performance. Valid values for maximum burst
length are 0.0 through 999.
General Parameters
WMM Mode
Wi‐Fi MultiMedia (WMM) is enabled by default. With WMM enabled, QoS prioritization
and coordination of wireless medium access is on. With WMM enabled, QoS settings on
the D‐Link controller control downstream trac owing from the access point to client
station (AP EDCA parameters) and the upstream trac owing from the station to the
access point (station EDCA parameters).
Disabling WMM deactivates QoS control of station EDCA parameters on upstream trac
owing from the station to the access point. With WMM disabled, you can still set some
parameters on the downstream trac owing from the access point to the client station
(AP EDCA parameters).
To disable WMM extensions, switch OFF.
To enable WMM extensions, switch ON.
Station EDCA Parameters
Queue
Queues are dened for dierent types of data transmitted from station‐to‐AP:
Data 0 (Voice)—Highest priority queue, minimum delay. Time‐sensitive data such as
VoIP and streaming media are automatically sent to this queue.
Data 1(Video)—Highest priority queue, minimum delay. Time‐sensitive video data is
automatically sent to this queue.
• Data 2 (best eort)—Medium priority queue, medium throughput and delay. Most
traditional IP data is sent to this queue.
Data 3 (Background)—Lowest priority queue, high throughput. Bulk data that
requires maximum throughput and is not time‐sensitive is sent to this queue (FTP
data, for example).
AIDS (Inter-Frame Space)
The Arbitration Inter‐Frame Spacing (AIFS) species a wait time for data frames. The wait
time is measured in slots. Valid values for AIFS are 1 through 255.
cwMin (Minimum
Contention Window)
This parameter is used by the algorithm that determines the initial random backo wait
time (window) for data transmission during a period of contention.
The value specied in the Minimum Contention Window is the upper limit (in milliseconds)
of a range from which the initial random backo wait time is determined.
The rst random number generated will be a number between 0 and the number
specied here.
If the rst random backo wait time expires before the data frame is sent, a retry counter is
incremented and the random backo value (window) is doubled. Doubling will continue
until the size of the random backo value reaches the number dened in the Maximum
Contention Window.

Table of Contents

Other manuals for D-Link DWC-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DWC-2000 and is the answer not in the manual?

D-Link DWC-2000 Specifications

General IconGeneral
Security algorithms802.1x RADIUS, WPA, WPA2
Data transfer rate1 Gbit/s
USB 2.0 ports quantity2
Ethernet LAN (RJ-45) ports4
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power consumption (typical)26.95 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Compatible productsDWL-8610AP, DWL-8600AP, DWL-6600AP, DWL-3600AP, DWL-2600AP
CertificationFCC Class A, CE Class A, C-Tick, IC, cUL, LVD
Package depth504 mm
Package width444 mm
Package height110 mm
Package weight5846 g
Pallet width1200 mm
Pallet length1100 mm
Pallet height (air)1095 mm
Pallet height (sea)2055 mm
Pallet gross weight (air)250560 g
Quantity per pallet (air)36 pc(s)
Shipping (inner) case width396 mm
Shipping (inner) case height480 mm
Shipping (inner) case length526 mm
Shipping (inner) case weight18755 g
Shipping (inner) case net weight17538 g
Number of cartons per pallet (air)12 pc(s)
Quantity per shipping (inner) case3 pc(s)
Harmonized System (HS) code85176990
Weight and Dimensions IconWeight and Dimensions
Weight3720 g
Dimensions (WxDxH)440 x 310 x 44 mm