Linea Lite GigE Series Camera Technical Specifications 151
External Output Details
The output signals can be used in programmable output mode such as strobe, event
notification, etc. (See Output Line Source
feature).
For the Single-Ended Open Collector outputs, the user supplied pull-up resistor value should
be between 1 kΩ and 10 kΩ depending on supply rail. Resistor Wattage should be calculated
accordingly.
Outputs are open (disabled) on power-up with the default factory settings.
A software reset will not reset the outputs to the open state if the outputs are active.
A user setup configured to load on boot will not reset the outputs to the open state if the
outputs are active.
The output signals are designed to prevent an output signal glitch on power-up or polarity
reversal.
Protection Circuit DC Ratings:
Output protected against shorts to ground or other voltages
Output maximum voltage of 26 V at 10 mA (at 60°C)