TECHNICAL FEATURES 
 
7 
 
SOFTWARE FEATURES 
READABLE CODE SYMBOLOGIES  
*  EAN/UPC (including Add-on 2 and Add-on 5  * Codabar 
  2/5 Interleaved  * Code 93 
*  Code 39  (Standard and Full ASCII)  * ABC Codabar 
*  Code 128  ISBT 128 
*  EAN 128  Pharmacode 
* = ACB Readable. Other symbologies available on request. 
Code Selection  up to ten different codes during one reading phase 
Decoding Safety  can enable multiple good reads of same code 
Headers and Terminators 
Up to 128-byte header string 
Up to 128-byte terminator string 
Operating Modes 
On-Line, Serial On-Line, Verifier, 
Automatic, Continuous, Test 
Configuration Modes 
• 
Genius™ utility program 
 
• Genius™ based Host Mode Programming 
• X-PRESS™ Functions 
Special Functions 
ACB (Advanced Code Builder) 
Motor Off 
Parameter Storage  Non-volatile internal Flash 
ENVIRONMENTAL FEATURES 
Operating temperature (Note 3) 
0 to +45 
°C (+32 to +113 °F) 
Storage temperature 
-20 to +70 
°C (-4 to +158 °F) 
Humidity max.  90% non condensing 
Vibration resistance  IEC 68-2-6 test FC 
  14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 
  2 g @ 70 to 200 Hz; 2 hours on each axis 
Shock resistance  IEC 68-2-27 test EA 
  30g; 11 ms; 3 shocks on each axis 
Protection class  IP65 
PHYSICAL FEATURES 
Mechanical dimensions  68 x 84 x 34 mm (2.68 x 3.31 x 1.34 in) 
Weight  330 g (11.6 oz) 
 
Note 1:  The features given are typical at a 25 °C ambient temperature (if not otherwise 
indicated). 
Note 2:  Further details given in par. 4.3. 
Note 3:  If the reader is used in high temperature environments (over 35 °C), use of the 
Beam-shutter is advised (see the Genius™ configuration program). 
 
  69