Codabar Enter/Exit Programming Mode
Product Reference Guide
167
CODABAR
The following options apply to the Codabar symbology.
Codabar Enable/Disable
When disabled, the reader will not read Codabar bar codes.
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Codabar check
character. When disabled, any check character in the label is treated as a data character
Codabar = Disable
Codabar = Enable
DEFAULT
$CCBEN00(CR)
$CCBEN01(CR)
Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM stan-
dard check char.
Codabar Check Character Calculation = Enable Modulo
10
check char.
DEFAULT
$CCBCC00(CR)
$CCBCC01(CR)
$CCBCC02(CR)