EasyManuals Logo

Datalogic Gryphon I GBT4400 User Manual

Datalogic Gryphon I GBT4400
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #256 background imageLoading...
Page #256 background image
References
254
Gryphon™ I GD44XX
/
GBT4400/GM440X
RS-232 Parameters
RS-232 Only
Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to
match the baud rate setting of the host device. With an improper baud rate setting, data may
not reach the host correctly.
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission of one
character and prepares the receiving device for the next character in the serial data stream. The
number of stop bits selected (one or two) depends on the number the receiving terminal is
programmed to accommodate. Set the number of stop bits to match host device requirements.
Parity
This feature specifies parity required for sending and receiving data. A parity check bit is the
most significant bit of each ASCII coded character. Select the parity type according to host
device requirements.
Select None when no parity bit is required.
Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an
odd number of 1 bi
ts are contained in the coded character.
Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an
e
ven number of 1 bits are contained in the coded character.
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with or without the
hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Handshaking
Control includes the following options:
RTS — RTS is asserted during transmissions. CTS is ignored.
RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and
X
OFF gate transmissions.
RTS On/CTS — RTS is always asserted. CTS gates transmissions.
RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and
controls enable and disable state
of scanner.

Table of Contents

Other manuals for Datalogic Gryphon I GBT4400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon I GBT4400 and is the answer not in the manual?

Datalogic Gryphon I GBT4400 Specifications

General IconGeneral
Wavelength650 nm
Scanner type2D
Yaw reading angle-40 - 40 °
Tilt reading angle0 - 360 °
Light levels (direct sunlight)0 - 100000 lx
Input voltage4.5 - 14.0 V
Battery capacity2100 mAh
Number of reads per charge60000
BluetoothYes
Dimensions (WxDxH)71 x 100 x 181 mm
CertificationChina RoHS, EU RoHS, IEC 60825 Class 2
Product colorBlack
LED indicatorsCharging, Power
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight245 g