Enter/Exit Programming Mode Batch Features
240
Gryphon™ I GD44XX
/
GBT4400/GM440X
Batch Features
Batch Mode
This option specifies whether to store labels in the handheld while disconnected from the base.
Options are as follows:
Disabled — The handheld will not store/batch labels.
Automatic — The handheld will store labels to RAM when the handheld goes out of
range and is discon
nected from the remote device.
Manual — The handheld will always store labels to F
lash memory. The user must manu-
ally send the stored labels to the remote device
using a special "batch send" label.
Send Batch
Use this bar code to initiate sending of labels stored in batch memory.
Batch Mode = Disabled
Batch Mode = Automatic
Batch Mode = Manual
DEFAULT
$CBTBM00(CR)
$CBTBM01(CR)
$CBTBM02(CR)
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction
with this bar code.
BatchSend