DA20-C1 Flight Manual
Supplement 1
Doc # DA202-C1 April 16, 2009 Page S1 - 5
Revision 24 DOT Approved
3. EMERGENCY PROCEDURES
3.3.4. Fire
A. Engine Fire during Engine-Start-Up on the Ground (EPU power connected).
1. Fuel Shut-off Valve CLOSED
2. Cabin Heat CLOSED
3. Mixture IDLE CUTOFF
4. Throttle FULL
5. GEN/BAT Master Switch OFF
6. Ignition Switch OFF
7. EPU Switch OFF
8. Evacuate Airplane immediately
4. NORMAL PROCEDURES
4.1. General
The following general procedure should be used to supply External Power to the aircraft for
purposes other than engine starting.
Power ON
1. Connect external power source to the EPU light ON
EPU receptacle.
2. EPU switch ON
3. GEN/BAT Master Switch (Battery only) ON if desired for charging
4. Avionics Master Switch ON if desired
CAUTION
IF THE BATTERY HAS BEEN DISCHARGED, IT IS ADVISABLE
TO LEAVE THE BATTERY ON CHARGE FOR A PERIOD OF
TIME LONG ENOUGH TO CHARGE THE BATTERY. CONSULT
MAINTENANCE PERSONNEL IF THE STATE OF CHARGE OF
THE BATTERY IS IN QUESTION. DO NOT FLY THE AIRCRAFT
WITH THE BATTERY IN A DISCHARGED STATE.
Power OFF
1. Electrical loads OFF
2. Avionics Master Switch OFF
3. GEN/ BAT Master Switch OFF
4. EPU switch OFF
5. LIFT EPU receptacle cover, PULL EPU light OFF
external power plug.