Doc # DA202-C1 April 16, 2009 Page S6 - 2
1. GENERAL
This supplement addresses the optional installation of the Vision Microsystems VM1000 engine
instrument package (Mod 31). Only portions of the flight manual affected by the installation are
included in this supplement.
2. OPERATING LIMITATIONS
2.1. Placards
1. Under the buttons of the VM 1000 main display.
3. EMERGENCY PROCEDURES
3.3. Emergency Procedures Checklist
3.3.1. Engine Failures
A. VM 1000 and EC 100 Display Malfunction
1. Instrument Circuit Breaker PRESS IN or PULL and RESET
NOTE
If indication cannot be restored take care not to shock cool the
engine during a descent. Electrical system voltage can be
monitored on M803 Clock / OAT / Volt Meter if installed.
4. Airspeed Do not exceed 115 KIAS
5. If indication cannot be restored Land at suitable airport
3.3.8. Electrical Power Failure
B. Generator Failure
GEN. Annunciator Illuminated
1. GEN/BAT Master Switch Cycle Generator Master Switch OFF
- ON
2. Generator Circuit Breaker If tripped, reset
3. Generator CONTROL Circuit Breaker If tripped, reset
4. If Generator can not be brought on-line Switch OFF all non-flight essential
electrical consumers. Monitor
Voltmeter. Land at nearest suitable
airport.
Revision 24 DOT Approved