DA20-C1 Flight Manual
Supplement 6
Doc # DA202-C1 April 16, 2009 Page S6 - 3
Revision 24 DOT Approved
NOTE
There is 30 minutes of battery power at a discharge load of 20
amperes when the battery is fully charged and properly
maintained. The amp meter monitors generator load which will
indicate low amps when the generator is off or has malfunctioned.
C. Low Voltage Indication (needle in yellow Arc)
LOW VOLTAGE INDICATION (NEEDLE IN YELLOW ARC) WHILE AIRPLANE ON
GROUND
1. Engine RPM Increase RPM until needle is in the
Green Arc. This should occur before
exceeding 1100 RPM.
2. Non-flight essential electrical consumers Switch OFF consumers until needle
is in the Green Arc.
3. If needle remains in the yellow arc and Discontinue any planned flight
the ammeter low generator amps activity
(display flashing)
LOW VOLTAGE INDICATION (NEEDLE IN YELLOW ARC) DURING FLIGHT
1. All non-flight essential electrical Switch OFF
consumers
2. If needle remains in the yellow arc and Generator Failure: Refer to
the ammeter low generator amps paragraph 3.3.2 (a)
(display flashing)
LOW VOLTAGE INDICATION (NEEDLE IN YELLOW ARC) DURING LANDING:
1. After landing proceed in accordance with
paragraph 3.3.2 (a).
WARNING
IF AT ANY TIME THE VOLTMETER NEEDLE INDICATES IN
THE RED ARC, YOU SHOULD LAND AT THE NEAREST
SUITABLE AIRPORT AND SERVICE THE AIRCRAFT
ACCORDINGLY BEFORE CONTINUING THE FLIGHT.