DA20-C1 Flight Manual
Emergency Procedures
Doc # DA202-C1 April 16, 2009 Page 3 - 9
Revision 24 DOT Approved
NOTE
Restore electrical power systematically allowing time to monitor
the system voltmeter and amp meter between the reconnection of
loads. Watch carefully for smoke.
6. Circuit Breakers Pull all circuit breakers.
7. Circuit Breakers Push BATTERY
8. GEN/BAT Master Switch ON BAT 1/2 only
9. Circuit Breakers Push GEN and GEN CONTROL
10. GEN/BAT Master Switch ON
11. Circuit Breakers Push AVIONICS and AVIONICS
MASTER
12. Avionics Master Switch ON
13. Circuit Breakers Push to activate systems as
required.
14. Radio ON
15. Land as soon as possible.
D. Electrical Fire including Smoke on the Ground
1. GEN/BAT Master Switch OFF
IF ENGINE RUNNING:
2. Throttle IDLE
3. Mixture IDLE CUTOFF
4. Fuel Shut-off Valve CLOSED
5. Ignition Switch OFF
6. Canopy open
7. Fire Extinguisher discharge as required
E. Cabin Fire during Flight
1. GEN/BAT Master Switch OFF
2. Cabin Air OPEN
3. Cabin Heat CLOSED
4. Fire Extinguisher discharge as required
5. Land as soon as possible
CAUTION
IF FIRE EXTINGUISHER IS USED, THE CABIN MUST BE
VENTILATED.