DA20-C1 Flight Manual
Supplement 1
Doc # DA202-C1 April 16, 2009 Page S1 - 6
Revision 24 DOT Approved
4.4. Normal Operation Checklist
In addition to those items contained in Section 4, Normal Operating Procedures, Preflight
Inspection, check the following items if this supplement is applicable to the aircraft you are
operating:
A. In-Cabin Check
Caution Lights (EPU) illuminated if EPU power available
B. Walk Around Check and Visual Inspection
Right Wing (C0001 to C0148, C0150)
Left Side of Fuselage (C0149, C0151 and Above)
EPU Receptacle ( For EPU START) check EPU connector inserted and
secure. Adequate power source
available.
EPU Receptacle (EPU not required for starting) check EPU power cord disconnected
and power cart clear of aircraft.
Before Starting Engine
The Before Starting Engine checklist from Section 4.4.2 is repeated in this section and includes
the steps for starting the engine with an external power source connected.
4.4.2. Before Starting Engine
1. Preflight Inspection performed
2. Pedals adjust, lock
3. Passenger Briefing performed
4. Safety Belts fasten
5. Parking Brake set
6. Flight Controls free
7. Fuel Shut-off Valve OPEN
8. Mixture FULL RICH
9. Throttle IDLE
10. Friction Device of Throttle Quadrant adjust
11. Avionics Master Switch OFF
12. EPU light check ON
13. EPU Switch ON
14. Voltmeter check 12-14 volts
15. GEN/BAT Master Switch ON
16. Generator Warning Light illuminated
17. Exterior Lights as required
18. Instrument Panel Lighting as required
19. Canopy close and secure
20. Canopy Unlocking Warning Light OFF