SM-300 Service Manual
13
3. SET UP
3.1 Scale Assembly
3.1.1 Set up
Step 1:
Remove top cushion pad
with accessories from
carton box.
Step 2:
Retrieve SM-300 scale kit
from carton box.
Step 3:
Place the cover as shown
at above.
Step 4:
Connect cable (Display
and keyboard) and mount
Elevated/Pole display [For
SM-300P, EV]
3.1.1 Level Adjustment
Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the center as shown
above.
Cove
r