6.3 Wireless Configuration For Model SM 300
Wireless communication has been implemented from SM90/500/300 ver14.53 onwards. The configuration
procedure is as follows.
For the first time installation, read default country spec and do initialization for scale. Reload default setting to
the RF Card by [Reset] button (on the RF Card) depressed with power on.
2. Go to SPEC SETTING MODE by [Rezero+141]
Enable spec317 for WIRELESS COMMUNICATION.
Enable scale’s Ethernet communication and configure it as Server type (spec49, 50).
Set spec135 for the last number of scale’s IP address. This IP tail should be as same as the WIRELESS IP tail.
E.g. if the IP address for WLAN is 192.168.0.200, this scale’s IP (SPEC135) should be set to ‘200’. But avoid
selecting ‘2’ as scale’s IP tail (spec135).
Quit with spec saving by key [PLU].
Go to Z Mode, set scale’s IP address by [Rezero+0416]. This IP address should be fixed as 010.0.0.xxx. (xxx is
set by spec135)
Power off/on scale with memory clearing. Scale will wait about 30sec for the RF Card rebooting.
3. Go to P44X ‘WIRELESS PROGRAMMING’ under Programming Mode.
Program ESSID according to the Access Point configuration. Max. 32 characters can be entered.
Program WEP according to the Access Point configuration and it’s PCMCIA card. There are two types of WEP.
One is 40 bit and another one is 104 bit. So the setting format is either xxxx-xxxx-xx for 40 bits or xxxx-xxxx-
xxxx-xxxx-xxxx-xxxx-xx for 104 bits. All x should be in Hex.
Set WIRELESS IP ADDRESS. This IP address is used for WLAN. Any communication from outside network to
scale will use this IP.
WIRELESS ROUTER ADDRESS and WIRELESS MASK can be set depending on the customer network setup.
Just leave them as any value if don’t use them.
Press key [Tare] to skip ADVANCE SETTINGS. Password would be required to enter this setting.
Press key [PLU] to save Wireless configuration.
5. Press key [Clear] to send the configuration to RF Card. Error message ‘ETHERNET COMM. ERROR’ will
be shown if the sending is unsuccessful.
6. Power off/on scale again. The new configuration will take effect on the RF Card.

Table of Contents

Other manuals for Digi SM-300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi SM-300 and is the answer not in the manual?

Digi SM-300 Specifications

General IconGeneral
BrandDigi
ModelSM-300
CategoryScales
LanguageEnglish

Related product manuals