SM-300 Service Manual
61
6.2.1.3 Window version client driver (Client /Server or Server/Workstation connection with PC)
When using the window client driver to communicate between PC and SM 300, the HOSTS file have to create
to set the scale IP address. Refer to Section 6.2.3 for connection method.
Go to the C:\WINDOWS directory.
Find a file HOSTS.SAM.
Open the file and at the bottom of the file:
Enter 192.168.0.1 [TAB] S0001
192.168.0.2 [TAB] S0002
192.168.0.3 [TAB] S0003
:
:
and so on until last scale number.
Save the file as file name HOSTS in the WINDOWS directory.
* 192.168.0.1 - Scale IP address; the last number is the scale number
S0001 - 0001 = scale number
** Above is the standard IP address for SM300 Ethernet communication. If the scale IP address is
changed, please change the IP address of the HOST file accordingly.
Refer to Windows Client Driver Manual on how to use and send data to the SM300.
6.2.1.4 SIS 98 (Client/Server or Server/Workstation Connection With PC)
For communication between PC and SM300 using SIS 98, only the scale IP address needs to be entering in the
SIS 98. The file HOSTS do not need to be created. Please refer to the SIS98 manual on how to enter the scale
IP address. Please refer to Section 6.2.3 for the connection method.
Before setting the SPEC setting of the scale, please check below.
* SIS98 is data management application software.