DISPLAY MESSAGES AND FAULT FINDING
4-12 25257 Issue 3 November 2013
6076 Check config, list mode
locked
List mode was assigned parameters in
the control configuration but blocked
with the activation code
Error list: System error message
Message category: Alarm
Remedial action: Save control
configuration again
6080 Check setting file n Read in settings "settings.cfg"
Error list: System error message
Message category: Alarm
Remedial action: Check control
version
6090 Error CMOS in setting
data n
Corrupt CMOS data - settings
Error list: System error message
Message category: Alarm
Remedial action: None
6091 Error CMOS in
production parameters n
Corrupt CMOS data - settings
Error list: System error message
Message category: Alarm
Remedial action: None
6092 Error CMOS data status
n
Corrupt CMOS data - settings
Error list: System error message
Message category: Alarm
Remedial action: None
6093 Error CMOS battery CMOS battery voltage
Error list: System error message
Message category: Alarm
Remedial action: Replace battery
6095 Error CMOS auto swap
data
Message category: Alarm
Remedial action: Reduce production
line speed
6100 Drive n does not exist Check drive/directory
Error list: System error message
Message category: Alarm
Remedial action: None
6102 Directory n does not exist Check drive/directory
Error list: System error message
Message category: Alarm
Remedial action: None
No. Error Text Description