Maintenance
A36951-C.doc
145/236
5. Remove the protective covering from the resonator wiring and disconnect the wires so
they do not become tangled or damaged during this operation.
6. Loosen the adjustment screws on the cannon-holder (see figure 1).
7. Bring the jet close to point A or point A' by rotating the cannon in the cannon holder
using a positioning tool at the top (see figure 2).
CAUTION Rotate in the direction shown on the diagram to avoid
unscrewing the fastening nut on the cannon.
Figure 1 Figure 2
Figure 1:
Preliminary cannon adjustment
1
Wires to be disconnected
2
Eccentrics
3
Adjustment screws
4
Position tool
5
Cannon holder
6
Location of protective cover
7
Cannon
Figure 2 :
Preliminary adjustment of jet in gutter
1
Jet
2
Gutter
3
Jet trajectory while cannon is turned
7
5
4
2
3
1
6