Servicing: 9040, 9040 IP65, 9040S
A36951-C.doc
118/236
Ŷ Automatic printer Drain/Flush
This procedure consists of two stages:
ʄ Flush the recovery gutter manually
1. Ensure printer in service and jet(s) are stopped and
then spray cleaning solution into the recovery gutter(s) for
20 seconds.
2. Shut down the printer normally and disconnect from the
main AC supply.
3. Close the gutter(s) and place a clean anti-clogging
protector under the nozzle(s)
ʄ Flush the printer automatically
Disconnect the industrial interface board ribbon cable.
Connect the "drain adapter" ribbon cable between the drain system and the industrial
interface board and then connect the main board ribbon to the open connector located on
in the center of the ribbon cable.
Motherboard ribbon cable
Drainage device ribbon cable
Flushing/Rinsing Tool