Maintenance
A36951-C.doc
165/236
Ŷ Hydraulic diagrams:
- - - Head drying kit option
2
1
3
4
5
6
7
8
10
12
11
13
9
14
15
17
16
18
19
20
21
22
28
23
24
25
26
27
1 Air supply
2 Head drying kit outlet
3 Pressurization outlet
4 Air filter
5 Condenser with fan
6 Additive tank
7 Ink tank
8 Restriction tube (0.3 mm)
9 Vacuum pump and motor
10 Pressure pump and motor
11 Ceramic restriction tube
12 Viscometer
13 Anti-pulse system
14 Pressure/temperature sensor
15 Rinsing electrovalve
16 Head filter – additive
17 Head filter - ink
18 Self-closing connection
19 Additive addition electrovalve
20 Gutter electrovalve
21 Viscometer drain electrovalve
22 Pressure electrovalve
23 Bleed electrovalve
24 One-way valve
25 Cannons
26 Flow control
27 Gutters
28 Fan

Table of Contents