Maintenance
A36951-C.doc
164/236
In normal operation (i.e. when no faults are present), this dialog box allows the user to
view:
Ƒ The different ink circuit management phases and sub-phases;
Ƒ Changes in accumulator, viscometer and vacuum reservoir levels;
Ƒ The status of all ink circuit electrovalves.
If an ink circuit fault is present, the phases are suspended and the printer changes to
"Standby" mode.
In standby mode:
Ƒ Jets are halted,
Ƒ Ink circuit electrovalves are closed, and the
Ƒ Compressed air supply is shut off.
Wait until the display shows "Sub-phase 21". You can now control the ink circuit
electrovalves to ensure that they are operating correctly.