Maintenance
A36951-C.doc
160/236
Ŷ Change coalescence filter:
Tools required:
Ƒ Open-end wrench.
1. Shut down the printer normally.
2. Open the door of the hydraulic compartment.
3. Pull out the ink circuit to access the filter (figures 1 and 2).
4. Undo the "filter side" nuts completly.
5. Remove the filter. Making a note of the flow direction arrows.
6. Fit the new filter, making sure that the arrow is pointing in the proper direction.
Figure 1: Front view Figure 2 : Rear view
1
Coalescence filter
2
Connector
1
2
1
2