EasyManua.ls Logo

Dover Markem Imaje 9040 - Faults Specific to 9040 Contrast Printers

Dover Markem Imaje 9040
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarms and faults
A36951-C.doc
180/236
Faults specific to 9040 Contrast printers
CAUTION
The ink circuit includes stirring motors located at the bottom of
the ink and recovery tanks. These are used for mixing the ink
continuously.
The printer must therefore never be disconnected from the
AC supply for more than two hours without draining and
flushing the system beforehand.
1- Low accumulator level 1a- The fault occurs after several jet starts or after
refresh sequences, which are excessively long.
Wait for the tank to fill up again.
1b- Contact Markem-Imaje Technical Assistance if
the fault persists.
2- Drain recovery tank 2a- The fault occurs after printhead cleaning or
cleaning solution addition sequences. Drain the
recovery tank via the drain tube provided.
2b- There is a fault on the recovery tank high-level
detection system. Contact Markem-Imaje Technical
Assistance.
3- Drain ink tank 3a- The fault occurs while the printer is being
drained. Drain the tank. Contact Markem-Imaje
Technical Assistance.
4- Regulator fault
4a- Activate regulator electrovalve. Press the
key to clear the fault.
4b- Contact Markem-Imaje Technical Assistance if
the fault persists.

Table of Contents

Other manuals for Dover Markem Imaje 9040

Related product manuals