Alarms and faults
A36951-C.doc
181/236
5- Ink fault 03 5a- Activate following electrovalves:
- Ink addition.
- Air transfer.
5b- Press the
key to clear the fault. Contact
Markem-Imaje Technical Assistance if the fault
persists.
6- Accumulator fault 04 6a- Activate following electrovalves:
- Air transfer.
- A/P.
- Ink addition.
6b- Press the
key to clear the fault. Contact
Markem-Imaje Technical Assistance if the fault
persists.
7- Accumulator fault 09 7a- Activate following electrovalves:
- Ink transfer.
- Air transfer.
7b- Press the
key to clear the fault. Contact
Markem-Imaje Technical Assistance if the fault
persists.
8- Initialization fault 05 8a- Activate following electrovalves:
- Charge.
- Discharge.
- Equi.-air ?
- A/P.
- Air transfer.
8b- Press the
key to clear the fault. Contact
Markem-Imaje Technical Assistance if the fault
persists.
9- Initialization fault 10 9a- Check inlet pressure and adjust if necessary.
9b- Activate following electrovalves:
- Discharge.
- Equi.-air.
9c- Press the
key to clear the fault. Contact
Markem-Imaje Technical Assistance if the fault
persists.