Maintenance
A36951-C.doc
167/236
2
1
3
4 5
6
7
8
10
12
11
13
9
14
15
17
16
18
19
20
21
22
23
24
25
26
27
28
29
31
30
1 Air supply
2 Discharge electrovalve
3 Atmospheric pressure
electrovalve
4 Charge electrovalve
5 Air transfer electrovalve
6 Equi-air electrovalve
7 Equi-visc electrovalve
8 Coalescence filter
9 Recovery tank
10 Additive tank
11 Ink tank
12 Pressure sensor
13 Coalescence filter
14 Coalescence filter
15 Stirrer motor
16 Additive addition electrovalve
17 Ink addition electrovalve
18 Stirrer motor
19 Viscometer
20 Visc. flow controller
21 Viscometer electrovalve
22 Ink filter
23 Ink transfer electrovalve
24 Head filter
25 Self-closing connections
26 Pressure electrovalve
27 Drain electrovalve
28 Single-jet cannon
29 Twin-jet cannon
30 Recovery gutter
31 Fan