Alarms and faults
A36951-C.doc
176/236
6- CPU fault. 6a- Contact Markem-Imaje Technical Assistance if
the fault persists.
7- Low ink level. 7a- Add ink to the tank concerned (max. 1/2 tank).
7b- The problem may be with the main board.
Contact Markem-Imaje Technical Assistance.
8- Low additive tank level
or
Additive tank empty
or
Solvent fault.
8a- Add additive to tank (max. 1/2 tank).
8b- Check that the additive addition electrovalve is
working correctly (Production/Maintenance/ELV
status modification). Check viscometer circuit.
8c- Contact Markem-Imaje Technical Assistance if
the fault persists.
9- Fan/compressed air 9a- Fan failure or no compressed air.
9b- Check fan connection and ensure that the fan at
the bottom of the cabinet rotates correctly. This fan
should run continuously as soon as the printer is
switched on.
9c- Ensure pressurization air present (except for
9040 Contrast models).
9d- The problem is on the main board. Contact
Markem-Imaje Technical Assistance.
10- Temperature 10a- The ambient temperature in the room where
the printer is installed is too high and is causing the
temperature inside the electronics compartment to
rise above 70° C. Modify installation.
10b- The problem is on the main board. Contact
Markem-Imaje Technical Assistance.
11- Viscosity 11a- Check viscosity measurement circuit.
11b- Check viscometer electrovalve operating
correctly by monitoring changes in viscometer
levels (Production/Maintenance/ELV status
modification)
11c- Contact Markem-Imaje Technical Assistance if
the fault persists.