External communications
A36951-C.doc
205/236
ʄ Jumpers and switches
Standard
position
ID LEGEND POSITION
FUNCTION / COMMENTS
1 2
S1-1 VAL VAL RS422 point-to-point link (just one printer
on the link).
S1-3 VAL not VAL RS422 point-to-multipoint link (printer
selected with VALID422).
1 2
S2_1 RXD 232 RS232 serial link mode selected
S2_3 RXD 422 RS422 serial link mode selected.
2 3
S3-3 TOP2 TOP2 DTOPIMP2 signal from optocoupled input
DTOP2.
S3-1 TOP2 not
TOP2
DTOPIMP2 signal from input DTOP1
(when operating with two heads and a
single DTOP cell)
2 3
S4-3 TAC2 TAC2 TACHYIMP2 signal from optocoupled
input TACHY2.
S4-1 TAC2 not
TAC2
TACHYIMP2 signal from input TACHY1
(when operating with two heads and a
single tachometer).
S5-3 INV2 INV2 DTOPIMP2 signal inverted.
1 2
S5-1 INV2 not INV2 DTOPIMP2 signal not inverted.
S6-3 INV1 INV1 DTOPIMP1 signal inverted.
1 2
S6-1 INV1 not INV1 DTOPIMP1 signal not inverted.
S7-3 SPROG2 SPROG
2
SPROGI2 signal operates in SPROG
mode.
1 2
S7-1 BUSY2 BUSY2 SPROGI2 signal operates in BUSY mode.
S8-3 SPROG1 SPROG
1
SPROGI1 signal operates in SPROG
mode.
1 2
S8-1 BUSY1 BUSY1 SPROGI1 signal operates in BUSY mode.
S9-3 T2 T2 24V alarm on J5 operates with 2 heads
1 2
S9-1 T2 not T2 24V alarm on J5 operates with one head

Table of Contents