EasyManua.ls Logo

Dover Markem Imaje 9040 - Page 74

Dover Markem Imaje 9040
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Editing a message
A36951-C.doc
75/236
ʄ First digit and last digit
Enter start and end values. These are the limit values between counter values changes.
The content of the counter increases if the first digit is lower than the last digit.. The
counter decrements if the first digit is greater than the last digit. When the counter reaches
the last digit, it starts again with the First digit.
ʄ Counter step
Enter counter increment value: between 00 and 99.
ʄ Batch counter
Specify number of objects in the batch. The standard counter is incremented when the
batch value is reached.
ʄ Incrementation type
Selected method used to change counter value. The method determines the way in which
the counter is incremented:
Ƒ OBJECT: on number of objects detected.(DTOP Signal)
Ƒ MESSAGE: on number of messages printed.
Ƒ EXT: on data on INCC1 and INCC2 inputs on the industrial interface board.
Ƒ OVERFLOW (Counter 2 only): when counter 1 reaches maximum value.
ʄ Leading zeros
Check this box if you want to show non-significant leading zeros in front of the counter
value. The position taken by the counter in the message always takes account of leading
zeros, whether they're printed or not.
NOTE Leading zeros cannot be deleted in barcodes.
ʄ Reinit./top object
Check this box if you want the counter to be reset to its initial value every time the "Top
object" input signal is activated.

Table of Contents

Other manuals for Dover Markem Imaje 9040

Related product manuals