English
18 Supplement Scio Four modules
Recommended separation distances from wireless
communication devices
To ensure that the functional integrity of this device is maintained,
there must be a separation distance of at least 1.0 m (3.3 ft)
between this device and wireless communication devices.
Relevant standards
This medical device meets other standards in addition to those
listed here. Information is available on request.
– IEC 60601-1 (2nd edition)
Medical electrical equipment
Part 1: General requirements for safety
– IEC 60601-1-2 (2nd edition)
Medical electrical equipment
Part 1-2: General requirements for safety, collateral stan-
dard: Electromagnetic compatibility;
Requirements and tests
– IEC 60601-1-4 (2nd edition)
Medical electrical equipment
Part 1-4: General requirements for safety, collateral stan-
dard: Programmable electrical medical systems
– ISO 21647
Medical electrical equipment
Particular requirements for the basic safety and essential per-
formance of respiratory gas monitors
– IEC 60601-1 (3rd edition)
Medical electrical equipment
Part 1: General requirements for safety
– IEC 60601-1-2 (3rd edition)
Medical electrical equipment
Part 1-2: General requirements for safety, collateral stan-
dard: Electromagnetic compatibility;
Requirements and tests
– IEC 60601-1-2 (4th edition)
Medical electrical equipment
Part 1-2: General requirements for safety, collateral stan-
dard: Electromagnetic disturbances;
Requirements and tests
– ISO 80601-2-55
Medical electrical equipment
Part 2-55: Particular requirements for basic safety and
essential performance of respiratory gas monitors
List of accessories
Radiated high-frequency dis-
turbances (IEC 61000-4-3)
80 MHz to 2.7 GHz: 3 V/m
Conducted high-frequency dis-
turbances (IEC 61000-4-6)
150 kHz to 80 MHz: 3 V, ISM
bands: 6 V
Electromagnetic fields in the
vicinity of wireless communica-
tion devices
Various frequencies from
385 MHz to 5785 MHz:
9 V/m to 28 V/m
Immunity against Test level and required elec-
tromagnetic environment
Accessory Part number
Power supply, 100 to 240 VAC, 50/60 Hz MS18508
WaterLock 2 6872130
Sample line 8290286
Sample gas return kit M32692
Sample gas scavenging hose 6873252
Connecting cables
SCIO/M500 cable, 0.8 m MS33986
SCIO/M500 cable, 2.2 m MS33987
Infinity Acute Care System (M540),
0.8 m
MS33168
Infinity Acute Care System (M540),
2.2 m
MS33167
Infinity Gamma XL with interface plate
or Infinity Docking Station (X5 connec-
tor), 0.3 m
MS13503
Infinity Gamma XL with interface plate
or Infinity Docking Station (X5 connec-
tor), 1.5 m
MS13864
Infinity Gamma XL (X8 connector),
2.1 m
MS15849 and
MS23211
Infinity Delta series/Gamma XXL/Vista
XL with Infinity Docking Station (X3
connector), 0.3 m
MS13504
Infinity Delta series/Gamma XXL/Vista
XL with Infinity Docking Station (X3
connector), 1.5 m
MS13865
Infinity Delta series/Gamma XXL/Vista
XL/Kappa XLT (X8 connector), 1.8 m
6871581
Y-cable for X8 connector MS24539
Vista 120 (RS232 connector), 2 m 8601473