Error number Explanation Remedy
10022 Reading-in the coding cannot be interrupted
(Position loss).
Do not stop the machine during the
reference run.
10034,
10044,
10064 Hook flap opened. Close hook flap.
10105 No reference stop possible. Do not switch on the Safe Stop
when carrying out the function.
10115 Impossible to stop during the displacement of
the transfer plate 
Do not switch on the Safe Stop
when carrying out the function. 
10125 Impossible to stop during the adjustment. Do not switch on the Safe Stop
when carrying out the function. 
10135 Impossible to stop while adjusting the lower
thread monitor for the class 806-121.
Do not switch on the Safe Stop
when carrying out the function. 
10145 Safe stop cannot be activated . Do not switch on the Safe Stop
when carrying out the function.
10155 Transfer plate cannot be determined. Do not switch on the Safe Stop
when carrying out the function. 
10167 Safe stop has reacted before the software has
stopped the machine.
Suppress the error in the safe stop
electronic system or 
the Software error
(only Service).
10174 Sequence error, the hook flap is opened, the
switch is defective or it is not available.
Close the hook flap or 
check the switch .
10182 Internal error Safe Stop still active. Suppress the error in the Safe
Stop electronic system or 
the Software error
(only Service).
10197 Sewing motor not initialised. Check power supply to he sewing
motor or 
check the interface conductors.
11022 No sewing motor positioning. Check the sewing motor or 
see for Software error.
11034 The transfer plate not in lower position following
the transfer to the sewing head.
Check limit switch for the lower
transfer plate position.
11041 Timeout, sewing head not in lower position at
the sewing start.
Check limit switch for the lower
sewing head position.
11101 Timeout, sewing head not in upper position after
sewing.
Check limit switch for the upper
sewing head position.
11111 Timeout, transfer plate not in upper position,
possibly after sewing without folding.
Check limit switch for the upper
transfer plate position.
11121 Timeout, sewing head not in upper position after
interrupting the transfer travel.
Check limit switch for the upper
sewing head position or see the
software error.
11131 Timeout, transfer plate not in upper position
after interrupting the transfer travel.
Check limit switch for the upper
transfer plate position.
12022 Left route, cycle control defective. 
Suppressing EMV cycle error
Suppress error in stepping motor
controller  
or the configuration of the stepping
motor controller bridges is wrong.
12032 Right route, cycle control defective. 
Suppressing EMV cycle error.
Suppress error in stepping motor
controller or 
the configuration of the stepping
motor controller bridges is wrong.
12072  Left route, cycle control defective. 
Suppressing EMV cycle error.
Suppress error in stepping motor
controller or 
the configuration of the stepping
motor controller bridges is wrong.
109