Error number Explanation Remedy
12082 Right route. Cycle control defective.
Suppress EMV cycle error.
Suppress stepping motor controller
error or
the configuration of the stepping
motor controller bridges is wrong.
12162 Motors already running. Suppress stepping motor controller
error or software error.
14011 Timeout, middle slide not in lower position. Check limit switch for the lower
middle slide position.
14021 Timeout, outer frame not in front position. Check limit switch for the front
outer frame position.
14031 Timeout, middle slide not in upper position. Check limit switch for the upper
middle slide position.
14041 Timeout, outer frame or middle slide not in lower
position.
Check limit switches for lower
middle slide position and lower
outer frame position
or remove the object located under
the outer frame.
14051 Timeout, outer frame not in upper position. Check limit switch for the upper
outer frame position.
14061 Timeout, outer frame not in rear positon. Check limit switch for the rear
outer frame position.
14081 Timeout, middle slide not returned in end
position.
Check limit switch for the rear
middle slide position.
14091 Timeout, middle slide not in front position. Check limit switch for the front
middle slide position.
14107 Pocket name not loaded. Check pocket programme name -
17011 Timeout, transfer plate not in upper position. Check limit switch for the upper
transfer plate position.
17021 At Stop, with defective light barrier.
Timeout, stacker part is not rolled out.
Roll-out motor does not run:
Electrical safety device has
reacted. Stop and start the
machine.
Roll-out motor runs 2 seconds:
Light barrier defective.
17031 Timeout, stacker switch, no end position. Check limit switch for stacker end
position.
17041,
17051,
17061
17077
17081 Timeout, advance roller switch, advance roller
not in upper position.
Check limit switch for the lower
advance roller position. Adjust the
advance roller mechanism.
17091 Timeout, advance roller switch. Advance roller
not in upper position after a stop.
Check limit switch for the lower
advance roller position. Adjust the
advance roller mechanism.
17101 Timeout, advance roller switch. Advance roller
not in upper position after the bobbin change
Check limit switch for the lower
advance roller position. Adjust
advance roller mechanism.
18017 Stepping motor end stage error or supply cable
defect after "free sequence".
Check supply cable or
suppress end stage error or
replace the end stage.
(only Service)
18027 Stepping motor not ready of initialisation. Check supply cable or
suppress end stage error or
replace end stage.
(only Service)
18034 Sewing head not in position after "sequence
free.
Check limit switch for the upper
sewing head position.
18044 Transfer plate not in upper position after
"sequence free".
Check limit switch for the upper
transfer plate position.