EasyManua.ls Logo

Eaton MVX9000 - Figure 5-21: Digital Input Terminal Setting 17

Eaton MVX9000
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group 30 — Inputs
5-20 MVX9000 User Manual
Descriptions of
Parameter Settings
Setting 17
A digital input terminal may be used for acceleration/deceleration inhibit. When
the command is received, acceleration and deceleration is stopped and the AC
drive maintains a constant speed. See Figure 5-21.
Figure 5-21: Digital Input Terminal Setting 17
Setting 18
Figure 5-22: Digital Input Terminal Setting 18
17:Acceleration/Deceleration inhibit
RO3 RO2 RO1
DI1 DI2
DI3
DI4
DI5
DI6
COM
AO+
AI1
+10V
AI2
DO1
DOC
COM
ON
Accel/Decel
Inhibit
Start
Command
ON ON ON
ON OFF
Time
Frequency
Master Frequency
Actual
Operation Frequency
Acceleration
Inhibit
Deceleration
Inhibit
Deceleration
Inhibit
Acceleration
Inhibit
18:Run Enable
RO3 RO2 RO1
DI1 DI2
DI3
DI4
DI5
DI6
COM
AO+
AI1
+10V
AI2
DO1
DOC
COM

Table of Contents