Appendix WinAQMS Mini DAS User manual 1.0
68
Add 3 channels with settings shown in table 9 to the new analyser and then hit OK.
Table 9 Settings for the NO, NOx, and NO
2
channels.
9841 NO Channel
9841 NOx Channel
9841 NO
2
Channel
System Channel #
8
9
10
Label
NO
NOx
NO2
Multiplier
1
1
1
Offset
0
0
0
Units
ppm
ppm
ppm
Decimal Places
4
4
4
High Alarm
0.1
0.4
0.1
Low Alarm
0
0
0
Alarm Number
8
9
10
Valid Data High
0
0
0
Valid Data Low
0
0
0
Channel Type
NO
NOX
NO2
Process
Average
Average
Average
Description
Nitrogen Monoxide
Nitrous Oxide
Nitrogen Dioxide
Log Report 1
Set (ticked)
Set (ticked)
Set (ticked)
Log Report 2
Set (ticked)
Set (ticked)
Set (ticked)
Log Report 3
Set (ticked)
Set (ticked)
Set (ticked)
Log Report 4
Set (ticked)
Set (ticked)
Set (ticked)
Out of Service
Unset (not ticked)
Unset (not ticked)
Unset (not ticked)
Serial Port Output
Set (ticked)
Set (ticked)
Set (ticked)
Alternate File Output
Set (ticked)
Set (ticked)
Set (ticked)